5320A Fluke Mexico Sales
If you are looking for a reliable supplier where you can purchase the 5320A Multifunction Electrical Tester Calibrator, you are in the right place. PARMEX AUTOMATIZACIÓN sells in the Mexico marketFluke all product groups belonging to the brand, with fast delivery times and competitive prices.
Request a price
Delivery time:
Determined at the time of quotation
VISA
Mastercard
Bank Transfer
Technical Specification
Precision Low Resistance Source
Ranges: 100 mΩ to 10 kΩ
Resolution: 3 ½ digits (continuously variable)
Maximum Current Ranges: 5 mA to 400 mA
Modes: 2-Wire and 4-Wire
Best 1 Year Specification: ± 0.2 % of setting
High Resistance Source (High voltage)
Ranges: 10 kΩ to 100 GΩ
Resolution: 4 ½ digits (continuously variable to 10 GΩ)
Maximum Voltage Ranges: 55 Vpk to 1575 Vpk
Best 1 Year Specification: ± 0.2 % of setting
Resistance Multiplier Adapter¹ (for high resistance source)
Resistance Ranges: 350 MΩ to 10 TΩ
Maximum Test Voltage: 5500 V dc
Best 1 Year Specification: Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value
Low Resistance Source (High current)
Ranges: 25 mΩ to 1.8 kΩ, 16 values
Maximum Current Ranges: 0.025 A to 30 A (continuous)
0.15 A to 40 A (short-term)
Best 1 Year Specification: ± 5 mΩ of setting
Loop Compensation: 0 to 10 Ω (Scan Mode)
0 to 2 Ω (Active Comp Mode)
Loop Compensation Specification: ± 1 % + 15 mΩ (Scan and active comp Mode)
Active Loop Compensation available on 5320A/VLC only
Line Leakage Current Source
Ranges: 0.1 mA to 30 mA
Resolution: 10 uA of setting
Test Voltage Ranges: 10 to 250 V
Modes: Passive, Differential, Substitute, Active
Best 1 Year Specification: ± 0.3% + 1 uA of setting
Residual Current Device
Trip Current Ranges: 3 to 3000 mA
Trip Current Modes: 0.5xI, 1xl, 1.4xI, 2xI, and 5xI
Best 1 Year Trip Current Specification: ± 1 % rms
Trip Time Ranges: 10 to 5000 ms
Best 1 Year Trip Time Specification: ± 0.25 ms
Multimeter
Voltage Ranges: 0 to 1100 V ac rms or dc
Voltage Resolution: 4 ½ digits
Best 1 Year Voltage Specification: ± 0.15% of reading + 5 mV
Current Ranges: 0 to 30 A ac rms or dc
Current Resolution: 4 ½ digits
Best 1 Year Current Specification: ± 0.15% of reading + 0.15 mA
Phantom Power: 0 to 33 kVA
Phantom Power Resolution: 3 digits
Best 1 Year Power Specification: √((V)² + (I)²)
Hipot Leakage Current Measurement Mode (Multimeter mode)
Current Range 0 to 300 mA acrms or cc
Current Resolution 4 ½ digits
Best 1 Year Specification ± 0.2% of reading + 0.21 mA
Hipot Timer Measurement Mode (Multimeter mode)
Timer Measurement Range 0.1 to 999 s
Timer Resolution 1 ms
Best 1 Year Specification 0.02% + 2 ms (dc)
0.02% + 20 ms (ac)
10 kV Divider Adapter¹ (for multimeter input)
Voltage Ranges: 0 to 10 kV ac peak or dc
Voltage Divider Ratio: 1000:1
Best 1 Year Specification: ± 0.3 % of reading + 5 V dc
± 0.5 % of reading + 5 V ac (50 or 60 Hz)
40 kV Probe² (for multimeter input) Accessory
Voltage Ranges: 0 to 40 kV ac peak or dc
Voltage Divider Ratio: 1000:1
Best 1 Year Specification: ± 0.5 % of reading + 10 V dc
± 0.5 % of reading + 10 V ac (50 or 60 Hz)
Voltage Calibrator Source (5320A/VLC only)
Ranges: 3 to 600 V ac or dc
Voltage Resolution: 4 digits
Frequency: 40 to 400 Hz
Frequency Resolution: 3 digits
Maximum Burden Current: 500 mA (ac)
5 mA (dc)
Best 1 Year Current Specification: ± 0.1 % of setting + 9 mV